摘要: 为使60Co辐照装置增加总活度为28878居里(1.07PBq)由7根活度不同的进口源棒的增源顺利启用,通过测定源到辐照位置的重复性为0.14%<1%,符合标准。测定从铁皮盖板到源中心的高度为90.3cm。五次升源所得剂量率(Gy/min)分别为:11.04、10.95、10.98、10.89、10.87,相对偏差为0.55%<1%,说明辐射场空间剂量率精确性高。计算辐照场空间分布的不均匀度U0=Dmax/Dmin=1.46(U0<1.5),表明在同一参考面上,辐射源剂量场剂量分布符合要求。

Abstract: Seven different-activity cobalt sticks with 28878 couriers had been added to 60Co irradiation facilities. Accuracy measurement cobalt source to irradiation position repeatability was 0.14%<1%.The height from iron cover board to center source was 90.3cm。The