中国农学通报 ›› 2014, Vol. 30 ›› Issue (4): 242-250.doi: 10.11924/j.issn.1000-6850.2013-1105
所属专题: 植物保护
朱赫 纪明山
收稿日期:
2013-04-17
修回日期:
2013-05-23
出版日期:
2014-02-05
发布日期:
2014-02-05
基金资助:
Received:
2013-04-17
Revised:
2013-05-23
Online:
2014-02-05
Published:
2014-02-05
摘要: 酶抑制法、免疫分析法和生物传感器在农药残留快速检测中发挥着越来越重要的作用,日益受到国际社会的高度重视。本研究详细介绍了酶抑制法、免疫分析法和生物传感器这3种方法的检测原理、研究现状及实际应用情况,并对农药残留快速检测技术的未来发展趋势进行了展望。
朱赫 纪明山. 农药残留快速检测技术的最新进展[J]. 中国农学通报, 2014, 30(4): 242-250.
[1] Lehotay S J. Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) approach for the determination of pesticide residues [M]. European Pesticide Residues Workshop, EPRW, Rome, Book of Abstracts, 2002. [2] Anastassiades M, Tasdelen B, Scherbaum E. New Developments in QuEChERS methodology[M]. EPRW 2006. Korfu, Books of Abstracts, 2006. [3] Anastassiades M, Scherbaum E, Tasdelen B, et al. Recent Developments in QuEChERS Methodology for Pesticide Multiresidue Analysis QuEChERS Pesticide Chemistry[M]. Crop Protection, Public Health, Environmental Safety; edited by H Ohkawa, H Miyagawa and PW Lee; WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim, 2007. [4] GB/T 5009.199—2003蔬菜中有机磷和氨基甲酸酯类农药残留量的快速检测[S].中华人民共和国卫生部,中国国家标准化管理委员会发布,2003. [5] GB/T 18630—2002蔬菜中有机磷及氨基甲酸酯农药残留量的简易检验方法酶抑制法[S].中华人民共和国国家质量监督检验检疫总局发布,2002. [6] NY/T 448—2001蔬菜上有机磷和氨基甲酸酯类农药残留毒快速检测方法[S].中华人民共和国农业部发布,2001. [7] 王林,王晶,张莹,杨大进,邓峰. 蔬菜中有机磷和氨基甲酸酯类农药残留量的快速检测方法研究 [J].中国食品卫生杂志,2003(1): 39-41. [8] 金伟. 农药残留快速检测体系研究与仪器研发[D].武汉:华中科技大学,2003. [9] NY/T 1157—2006农药残留检测专用丁酰胆碱酯酶[S].中华人民共和国农业部发布,2006. [10] GB 2763—2012 食品安全国家标准食品中农药最大残留限量[S].中华人民共和国卫生部, 中华人民共和国农业部发布, 2012-11-16. [11] Macrom P, Gee S, Hammock B D. Immunochemical techniques for environmental analysis II. Antibody production and immunoassay development[J]. Trends in Analytical Chemistry,1995,8(14): 415-425. [12] Yalow R S, Berson S A. Immunoassay of endogenous plasma insulin in man[J], J Clin Invest 1960,39:1157-1175 [13] Langone J J, Van Vunakis H. Radioimmunoassay for dieldrin and dldrin[J]. Res. Commun. Chem. Pathol. Pharmacol.,1975,10: 163-171. [14] Levitt T. Radioimmunoassay for paraquat[J]. Lancet, 1977, 2(8033): 358. [15] Lukens H R, Williams C B, Levison S A. Fluorescence immunoassay technique for detecting organic environmental contaminants[J]. Environ. Sci. Technol., 1977,11(3):292-297. [16] Wing K D, Hammock B D. Stereoselectivity of a radioimmunoassay for the insecticide S-bioallethrin[J]. Experientia, 1979, 35(12):1619-1620. [17] Cook C E, Ballentine N H, Seltzman T B, et al. Warfarin enantiomer disposition: determination by stereoselective radioimmunoassay[J]. J Pharmacol Exp Ther, 1979,210(3):391-398. [18] Engvall E, Perlmann P. Enzyme-linked immunosorbent assay (ELISA) [J]. Quantitative assay of immunoglobulin G, Immunochemistry, 1971, 8(9):871-874. [19] van Weemen B K, Schuurs A. Immunoassay using antigen-enzyme conjugates[J]. FEBS Letts, 1971,15(3):232-236. [20] Hennion M C, Barcelo D. Strengths and limitations of immunoassays for effective and efficient use for pesticide analysis in water samples: A review[J]. Anal. Chim. Acta, 1998,362(1):3-34. [21] Dankwardt A. Immunochemical assays in pesticide analysis[M]. In: Encyclopedia of Analytical Chemistry, Meyers, R. A. (Ed.), 1-26, Wiley: Chichester, UK, 2001. [22] Watanabe E, Baba K, Eun H, et al. Application of a commercial immunoassay to the direct determination of insecticide imidacloprid in fruit juices[J]. Food Chem., 2007,102(3):745-750. [23] 殷祥刚,尹丽梅,胥传来.有机磷农药多残留免疫分析方法研究进展[J].食品科学,2008,29(10):684-687. [24] 丁晓燕,卢平,胡德禹.酶联免疫分析方法在有机磷农药多残留检测中的应用研究进展[J].山地农业生物学报,2011,30(6):547-552. [25] 王春梅,程敬丽,刘毅华,等.拟除虫菊酯类农药酶免疫分析方法研究进展[J].农药学报,2008,10(1):15-22. [26] 任克维,刘蕊,王鸣华.农药多残留免疫分析研究进展[J].农药, 2010,49(8):555-558. [27] 王姝婷.农药多簇人工抗原的免疫特异性及多残留免疫金技术[D].杭州:浙江大学,2008. [28] Ward C M, Wilkinson A P, Lee H A, et al. Monoclonal anti-idiotype antibody mimicking the pesticide binding site of cutinase: potential for broad specificity organophosphate recognition[J]. J Immunol Meths, 1999, 224(1-2):197-202. [29] Coons A H, Creech H J, Jones R N. Immunological properties of an antibody containing a fluorescent group[J]. Proc Soc exp Biol Med, 1941,47:200-202. [30] Riggs J L, Seiwald R J, Burckhalter J H, et al. Isothio cyanate compounds as fluorescent labeling agents for immune serum[J]. Am J Pathol 1958,34:1081-1097. [31] Halmann M, Velan B, Sery T. Rapid identification and quantitation ofsmall numbers of microorganisms by a chemiluminescent immunoreaction[J]. Appl Environ Microbiol, 1977,34(5):473-477. [32] Liu B, Yang Y H, Wu Z Y, et al. A Potentiometric Acetylcholinesterase Biosensor Based on Plasma-Polymerized Film [J]. Sensors and Actuators B, 2005, 104(20):186-190. [33] La Rosa C, Pariente F, Hernández L, et al. Amperometric Flow-Through Biosensor for the Determination of Pesticides[J]. Analytica Chimica Acta, 1995, 308(1/3):129-136. [34] Andreescu S, Avramescu A, Bala C, et al. Detection of Organophosphorus Insecticides with Immobilized Acetylcholinesterase - Comparative Study of Two Enzyme Sensors [J]. Analytical and Bioanalytical Chemistry, 2002,374(1):39-45. [35] Wan K, Chovelon J M, Jaffrezic-Renault N, et al. Sensitive detection of pesticide using ENFET with enzymes immobilized by cross-linking and entrapment method[J]. Sens Actust (B), 1999,58 (1/3):399-408. [36] Andreou V G, Clonis Y D. A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use[J], Biosens Bioelectron. 2002,17(1/2):61-69. [37] White B J, Legako J A, Harmon H J. Extended lifetime of reagenfless detector for multiple inhibitors of acetylcholinesterase [J]. Biosens Bioelectren, 2003,18:729-734. [38] Makower A, Halámek J, Skládal P, et al. New principle of direct real-time monitoring of the interaction of cholinesterase and its inhibitors by piezolectric biosensor[J]. Biosens Bioeleetron, 2003,18 (11):1329-1337. [39] Mionetto N, Rouillon R, Marty J L. Inhibition of acetylcholinesterase by organophosphorus and carbamate compounds. Studies on free and immobilized enzymes[J]. Z. Wasser-Abwasser -Forsch, 1992,25(3):171-174. [40] Andreescu S, Avramescu A, Bala C, et al. Detection of organophosphorus insecticides with immobilized acetylcholinesterase-comparative study of two enzyme sensors[J]. Anal Bioanal Chem. 2002,374(1):39-45. [41] Karousos N G, Aouabdi S, Way A S, et al. Quartz Crystal Microbalance Determination of Organophosphorus and Carbamate Pesticides[J]. Analytica Chimica Acta, 2002,469(2):189-196. [42] Mulchandani P, Mulchandani A, Kaneva I, et al. Biosensor for direct determination of organophosphate nerve agents. 1. Potentiometric enzyme electrode[J]. Biosens Bioelectron, 1999, 14: 77-85. [43] Chough S H, Mulchandani A, Mulchandani P, et al. Organophosphorus hydrolase-based amperomet ric sensor: modulation of sensitivity and substrate selectivity[J]. Electroanalysis, 2002,14(4):273-276. [44] Sch?ning M J, Arzdorf M, Mulchandani P, et al. A capacitive field-effect sensor for the direct determination of organophosphorus pesticides[J]. Sens. Actuat, 2003,91:92-97. [45] Flounders A W, Singh A K, Volponi J V, et al. Development of sensors for direct detection of organophosphates. Part II: Sol-gel modified field effect transistor with immobilized organophosphate hydrolase[J]. Biosens Bioelectron, 1999,14(8/9):715-722. [46] Russell R J, Pishko M V, Simonian A L, et al. Poly(ethylene glycol) hydrogel-encapsulated fluorophore-enzyme conjugates for direct detection of organophosphorus neurotoxins[J]. Anal Chem, 1999,71 (21):4909-4912. [47] Wu C F, Cha H J, Rao G, et al. A green fluorescent protein fusion strategy for monitoring the expression, cellular location, and separation of biologically active organophosphorus hydrolase[J]. Biotechnol, 2000,54:78-83. [48] Lima F D, Lucca B G, Barbosaa Ant?nio M J, et al. Biosensor Based on Pequi Polyphenol Oxidase Immobilized on Chitosan Crosslinked with Cyanuric Chloride for Thiodicarb Determination [J]. Enzyme and Microbial Technology, 2010,47(4):153-158. [49] Kim G Y, Shim J, Kang M S, et al. Optimized Coverage of Gold Nanoparticles at Tyrosinase Electrode for Measurement of a Pesticide in Various Water Samples[J]. Journal of Hazardous Materials, 2008,156(1/3):141-147. [50] Sánchez F G, D??az A N, Peinado M C R, et al. Free and Sol-Gel Immobilized Alkaline Phosphatase-Based Biosensor for the Determination of Pesticides and Inorganic Compounds[J]. Analytica Chimica Acta , 2003,484(1):45-51. [51] Mazzei F, Botrè F, Montilla S, et al. Alkaline Phosphatase Inhibition Based Electrochemical Sensors for the Detection of Pesticides[J]. Journal of Electroanalytical Chemistry, 2004,574(1): 95-100. [52] Mazzei F, Botrè F, Botrè C. Acid Phosphatase/Glucose Oxidase-Based Biosensors for the Determination of Pesticides[J]. Analytica Chimica Acta , 1996, 336(1):67-75. [53] Moccelini S K, Vieira I C, de Lima F, et al. Determination of Thiodicarb Using a Biosensor Based on Alfalfa Sprout Peroxidase Immobilized in Self-Assembled Monolayers[J]. Talanta, 2010,82(1): 164-170. [54] Andreou V G, Clonis Y D. Novel Fiber-Optic Biosensor Based on Immobilized Glutathione S-Trans-ferase and Sol-Gel Entrapped Bromcresol Green for the Determination of Atrazine[J]. Analytica Chimica Acta, 2002,460(2):151-161. [55] Grennan K, Strachan G, Porter A J, et al. Atrazine Analysis Using an Amperometric Immunosensor Based on Single-Chain Antibody Fragments and Regeneration-Free Multi-Calibrant Measurement[J]. Analytica Chimica Acta , 2003,500(1/2):287-298. [56] Valera E, Muniz D, Rodriguez A. Fabrication of Flexible Interdigitated μ-Electrodes (FIDμEs) for the Development of a Conductimetric Immunosensor for Atrazine Detection Based on Antibodies Labelled with Gold Nanoparticles[J]. Microelectronic Engineering , 2010,87(2):167-173. [57] Plekhanova Y V, Reshetilov A N, Yazynina E V, et al. A New Assay Format for Electrochemical Immunosensors: Polyelectrolyte-Based Separation on Membrane Carriers Combined with Detection of Peroxidase Activity by pH-Sensitive Field-Effect Transistor[J]. Biosensors and Bioelectronics, 2003,19(2):109-114. [58] Ionescu R E, Gondran C, Bouffier L, et al. Label-Free Impedimetric Immunosensor for Sensitive Detection of Atrazine[J]. Electrochimica Acta, 2010,55(21):6228-6232. [59] Singh P, Onodera T, Mizuta Y, et al. Dendrimer Modified Biochip for Detection of 2,4,6 Trinitrotoluene on SPR Immunosensor: Fabrication and Advantages[J]. Sensors and Actuators B, 2009,137 (2):403-409. [60] Cummins C M, Koivunen M E, Stephanian A, et al. Application of Europium (III) Chelate-Dyed Nanoparticle Labels in a Competitive Atrazine Fluoroimmunoassay on an ITO Waveguide[J]. Biosensors and Bioelectronics, 2003,21(7):1077-1085. [61] Long F, Shi H C, He M, et al. Sensitive and Rapid Detection of 2, 4-Dicholorophenoxyacetic Acid in Water Samples by Using Evanescent Wave All-Fiber Immunosensor[J]. Biosensors and Bioelectronics, 2008,23(9):1361-1366. [62] Boujday S, Nasri S, Salmain M, et al. Surface IR Immunosensors for Label-Free Detection of Benzo[a]pyrene[J]. Biosensors and Bioelectronics, 2010, 26(4):1750-1754. [63] March C, Manclús J J, Jiménez Y, et al. A Piezoelectric Immunosensor for the Determination of Pesticide Residues and Metabolites in Fruit Juices[J]. Talanta, 2009,78(3):827-833. [64] Kaur J, Singh K V, Schmid A H, et al. Atomic Force Spectroscopy-Based Study of Antibody Pesticide Interactions for Characterization of Immunosensor Surface[J]. Biosensors and Bioelectronics, 2004,20(2):284-293. [65] Suri C R, Kaur J, Gandhi S, et al. Label-free Ultra-Sensitive Detection of Atrazine Based on Nanomechanics[J]. Nanotechnology, 2008,19(23):235502-235600. [66] Mulchandani P, Chen W, Mulchandani A. Microbial Biosensor for Direct Determination of Nitrophenyl-Substituted Organophosphate Nerve Agents Using Genetically Engineered Moraxella sp. [J]. Analytica Chimica Acta, 2006,568(1/2):217-221. [67] Kumar J, Jha S K, D’ Souza S F. Optical Microbial Biosensor for Detection of Methyl Parathion Pesticide Using Flavobacterium sp. Whole Cells Adsorbed on Glass Fiber Filters as Disposable Biocomponent[J]. Biosensors and Bioelectronics, 2006,21(11): 2100-2105. [68] Nowicka A M, Kowalczyk A, Stojek Z, et al. Nanogravimetric and Voltammetric DNA-Hybridization Biosensors for Studies of DNA Damage by Common Toxicants and Pollutants[J]. Biophysical Chemistry, 2010,146(1):42-53. [69] Jenkins A L, Yin R, Jensen J L. Molecularly Im- printed Polymer Sensors for Pesticide and Insecticide Detection in Water[J]. Analyst, 2001,126:798-802. [70] Xie C, Gao S, Guo Q, et al. Electrochemical Sensor for 2, 4-Dichlorophenoxy Acetic Acid Using Molecularly Imprinted Polypyrrole Membrane as Recognition Element[J]. Microchimica Acta, 2010,169(1):145-152. [71] Pellicer C, Gomez-Caballero A, Unceta N, et al. Using a Portable Device Based on a Screen-Printed Sensor Modified with a Molecularly Imprinted Polymer for the Determination of the Insecticide Fenitrothion in Forest Samples[J]. Analytical Methods, 2010,2(9):1280-1285. [72] He J, Liu Y, Fan M, et al. Isolation and Identifi- cation of the Dna Aptamer Target to Acetamiprid[J]. Journal of Agricultural and Food Chemistry, 2011,59(5):1582-1586. |
[1] | 郭海涛 薛晓明 侯森林. 大灵猫、小灵猫的直针毛红外光谱比较研究[J]. 中国农学通报, 2012, 28(29): 58-61. |
阅读次数 | ||||||
全文 |
|
|||||
摘要 |
|
|||||